In modern industrialized countries, more than half the total electrical Energy used is converted to mechanical energy through AC induction motors. Induction motors are extensively used in industrial and household appliances and consume more than 50% of the total generated electrical energy. Single-phase induction motors are widely used in home appliances and industrial control. During the last few years, the concept of speed and torque control of asynchronous motor drives has gained significant popularity. This way, it has been possible to combine the induction-motor structural robustness with the control simplicity and efficiency of a direct current motor. This evolution resulted to the replacement of the dc machines by induction motors in many applications in the last few years. Earlier only dc motors were employed for drives requiring variable speeds due to facilitate of their speed control methods.
The conventional methods of speed control of an induction motor were either too extravagant or too inefficient thus limiting their application to only constant speed drives. They are used to drive pumps, fans, compressors, mixers, agitators, mills, conveyors, crushers, machine tools, cranes, etc. This type of electric motor is so popular due to its simplicity, reliability, less maintenance and low cost. Today, with advancements in power electronics, microcontrollers, and digital signal processors (DSPs), electric drive systems have improved drastically. Initially the principle of speed control was based on steady state consideration of the induction motor. V/f control was the commonly used one for the open-loop speed control of drives with low dynamic requirements which is the focus of this study.
This section presents the conceptual and related literature from various entity where the study anchored upon to provide evidence and significant review of the topic grounded with the current study.
Deraz1, et al.[2004], has been presented a new current- limiting soft-starter for a three-phase induction motor drive system using pulse width modulation (PWM) AC chopper. A novel configuration of three-phase PWM AC chopper using only four insulated gate bipolar transistors (IGBTs) is also proposed. It requires only one current sensor. The duty ratio of the chopper IGBTs is obtained from the closed-loop current control in order to limit the motor starting current at a preset value. Only two complementary gate pulses are obtained from the control circuit to control the four IGBT switches.
Pratibha Naganathanl, et al. [2017],has discussed Two cascaded two-level inverters can synthesize three- level voltage space vector For the cascaded three-level inverter controlled induction motor, this study proposes a five-level torque controller (FLTC)-based direct torque control (DTC) method especially for improving steady-state motor torque performance and retaining the high dynamic performance.
- Prathap Reddy, et al. [2003], has suggested two cascaded two level inverters can synthesize three-level voltage space vector for. the cascaded three-level inverter controlled induction motor, this study proposes a five-level torque controller(FLTC)-based direct torque control (DTC) method especially for improve steady-state motor torque performance and retaining the high dynamic performance.
Gonzalez-Prieto, et al. [2005], has been presented the most serious and recent competitor to the standard field oriented control (FOC) for induction motors (IM) is the finite control set model predictive control (FCS-MPC), has discussed Direct torque control (DTC) has been widely used as an alternative to traditional field-oriented control (FOC) methods for three-phase drives, has been suggested Direct torque control (DTC) has been recently used for the development of high performance five-phase induction motor (IM) drives, This work analyzes the fault-tolerant capability of six-phase drives with parallel converter supply. Different scenarios considering up to three faults for single and two neutral configurations are examined, optimizing off-line the post- fault currents and modifying accordingly the control strategies. Has discussed A model predictive control scheme for multiphase induction machines, configured as multi three-phase. Complete details about the predictive control scheme and adopted flux observer are included, has been suggested Direct torque control (DTC) has been recently used for the development of high performance five-phase induction motor (IM) drives, where normal operation of the system has been usually considered and the ability of DTC to manage the situation has been analyzed in comparison with different rotor field-oriented control (RFOC) strategies.
Mario Bermudez, et al. [2006], has discussed Three-phase machines are the industry standard for electrical drives, but the inherent fault tolerance of multiphase machines makes them an attractive alternative in applications requiring high reliability. This novel strategy is then combined with minimum losses and maximum torque criteria to obtain a variable current injection method that minimizes the drive derating, reduces the copper losses and improves the braking transients. Experimental results confirm the successful performance in the different zones for the case of a six-phase induction motor drive.
Toliyat et al, (2003), due to the high order and nonlinearity of the dynamics of an induction motor, estimation of the angle speed and rotor position without the measurement of mechanical variables becomes a challenging problem. The advantages of position and speed sensorless induction motor drives are to reduced hardware complexity and lower cost, reduce size of drive machine, eliminate of sensor cable, better noise immunity, increasing reliability and less maintenance requirements.
Benchaib et al (1999) presented a sliding mode controller with rotor flux estimation for induction motor drives. Rotor flux was also estimated using a sliding mode observer. Most methods are basically based on the Model Reference Adaptive System schemes (MRAS) (Cirrincione and Pucci, 2005).
Bilal et al, (2004) used a reactive-power-based-reference model derived in both motoring and generation modes but one of the disadvantages of this algorithm is its sensitivity to detuning in the stator and rotor inductances. The basic MRAS algorithm is very simple but its greatest drawback is the sensitivity to uncertainties in the motor parameters.
Ouhrouche, (2002) proposed another method based on the Extended Kalman Filter (EKF) algorithm. The EKF is a stochastic state observer where nonlinear equations are linearized in every sampling period. An interesting feature of the EKF is its ability to estimate simultaneously the states and the parameters of a dynamic process. This is generally useful for both the control and the diagnosis of the process.
Negm (2000) discloses the advances in microprocessor and power electronics which gives permission to implement modern techniques for induction machines such as field oriented control also known as vector control. This provides higher efficiency; lower operating costs and reduces the cost of drive components. In sensorless field oriented control, the speed and/or position are not directly measurable; their values are estimated using other parameters such as phase voltages and current, that are directly measured. Sensorless drives are becoming more and more important as they can eliminate speed sensors maintaining accurate response. Monitoring only the stator current and voltages, it is possible to estimate the necessary control variables.
Kyo and Frede, (2006) used the EKF algorithm to simultaneously estimate variables and parameters of the IM in healthy case and under different Induction Motor faults. An extended Kalman filter was also used by Kim et al (1994) for speed estimation of vector controlled induction motor drive. Unfortunately, Cheng and Hai, (2002) stated that this approach contains some inherent disadvantages such as its heavy computational requirements and difficult design and tuning procedure. Luenberger Observer for state estimation of Induction motor was used in. The Extended Luenberger Observer (ELO) is a deterministic observer which also linearizes the equations in every sampling period. There is other type of methods for state estimation that is based on the intelligent techniques is used in the recent years by many authors (Sbita and Ben, 2007).
Ignacio González-Prieto1, et al. [2014], has suggested, a direct torque and flux control is described for a six-phase asymmetrical speed and voltage sensor less induction machine (IM) drive, based on non-linear back stepping control approach. First, the decoupled torque and flux controllers are developed based on Lyapunov theory, using the machine two axis equations in the stationary reference frame.
Seyed Mohd. J. R. Fatemi, et al. [2014], has been presented distributed generation (DG) into low voltage (LV) systems demands that the generation system remain grid connected during voltage sags to ensure the operational stability. has been proposed A variable- frequency drive (VFD) having a 440-V front-end current source rectifier (CSR) interface to a voltage source inverter (VSI) feeding a Permanent-Magnet Axial-flux Air Core motor combination is a solution for low-horsepower pump and fan control that is both power dense and compatible with a shipboard environment. Power density and efficiency comparisons are made between equivalent CSR/VSI- and voltage source- conversion-based VFDs to demonstrate that the CSR/VSI-based VFD is more power dense, has presented the implementation of the controller is based on the machine air gap flux which is measured by detecting the third harmonic component of the stator phase voltages. This new controller does not require any sensors in the air gap of the machine nor does it require complex computations. Only access to the stator neutral connection is necessary to measure the air gap flux has been suggested Comprehensive analysis of the starting period of inverter-fed large induction motors reveals that these motors are subjected to additional components of pulsating torsional torque. These torque pulsations may coincide with the natural torsional frequency of the large motor system and produce hazardous shaft torque oscillations. To alleviate the torsional toque problem and limit the motor starting current, a constant air-gap flux using slip frequency control scheme is proposed to operate the motor inverter.
Yifan Tang,et al. [2001], has discussed Variable-speed constant- frequency generating systems are used in wind power, hydro power, aerospace, and naval power generations to enhance efficiency and reduce friction. In these applications, an attractive candidate is the slip power recovery system comprising of doubly excited induction machine or doubly excited brushless reluctance machine and PWM converters with a dc link.
- Rahman, et al.[1995], has discussed steady state and transient operation of thyristor and diode controllers for variable voltage control of three-wire 3-phase induction motors is considered.
Takayoshi Matsuo, et al. [1977], has been presented the usual method of induction motor torque control uses the indirect field orientation principle in which the rotor speed is sensed and slip frequency is added to form the stator impressed frequency. In this paper two new field oriented control schemes are presented which employ rotor end ring current detection and thereby remove the dependence of the controller accuracy on temperature so that the controller is entirely independent of rotor time constant variations. The field orientation schemes do not require an incremental encoder for rotor position sensing. The motor torque can be accurately controlled even down to zero speed operation. has been suggested Adjustable-speed operations of induction motors are required to maintain their maximum efficiency levels. This can be achieved by constant slip operation of induction motors. In applications like submersible motor pumps, variable-speed operation is also needed to obtain maximum efficiency at all loads. To maintain a constant slip operation of induction motors, it is necessary to monitor the motor’s speed from its shaft. Conventional methods use speed sensors attached to the shaft. Speed monitored by these sensors is fed back to maintain constant slip operation in scalar control schemes. Has been proposed a definite relation exists between the flux level, torque and slip speed of a vector controlled induction motor. An untuned vector controller generates an inappropriate slip frequency that changes the operating flux of the machine. The torque characteristic is analysed with three aspects of magnetic state: true saturation curve, hard-limit saturation curve, and constant inductance model. Has been suggested adjustable-speed drive is attractive for pump, compressor, and other centrifugal load applications due to its flexibility and high operating efficiency, compared with the conventional constant-speed drive system. The drive system can successfully run in the full speed range with the proposed control method and control sequences.
Jose Titus, et al. [2005], has studied ability of an electrical drive to continue operation without tripping in spite of short duration voltage sags or power supply interruptions is known as Power Failure Ride through capability. Critical production processes in industries require the drives to smoothly ride-through during momentary power interruptions. The reliability of the drive is dependent on the maximum duration for which a total power supply failure can be tolerated without process interruption, has suggested proposes a simple method for single switch and double switches open-circuit fault diagnosis in pulse width modulated voltage-source inverters (PWM VSIs) for vector controlled induction motor drives, which also applies to secondary open-circuit fault diagnosis. According to the phase angle of one phase current, the repetitive operation process of VSI is evenly divided into six operating stages by certain rules. At each stage, only three of the six power switches exert a vital influence on this operation and the others make a negligible influence, uses a disturbance observer for various types of induction motor control was evaluated. The disturbance observer is designed to have fast response that is ten times faster than the current controller for vector control. The voltage error is efficiently corrected using the proposed method, and the current distortion can be reduced by approximately 1/3.
Limitations
The major problem seen in the above research is that induction motor is sensitive to deviation in estimated motor parameters values used in the control algorithm from their actual values. In addition, the parameters values may need to be updated while the motor is running, if there are large changes in the operating temperature and flux magnitude because resistances values depend on the temperature and inductances values changes due to flux saturation. Direct vector control requires values of the rotor leakage inductance, and the ratio of the rotor inductance to the mutual inductance while the first parameter has a constant value independent of temperature and flux, the second parameter is moderately affected by the saturation of the main flux path in the motor. In addition, there is the need for the special flux sensors, which need frequent maintenance and impose limitation in the motor mounting. If the sensorless form of direct method is implemented, the value of the stator resistance is sensitive to temperature changes. Indirect vector control is more sensitive to parameters values inaccuracy than direct vector control. The value of the rotor time constant (Lr/Rr) is used in the slip speed calculation this parameter is sensitive to temperature, skin effect and flux level. Errors in the slip speed calculation produce coupling between the flux and torque producing currents and result in a torque response with possible overshoot/undershoot and a steady state error. The need of special position incremental encoder is another disadvantage of the method. Beside the above limitations, voltage /frequency method is complex and need fast speed microcontrollers.
REFERENCE
Said A. Deraz andHaitham Z. Azazi1,“Current limiting soft starter for three phaseinduction motor drive system using PWM AC chopper”, IET Power Electronics.2004, P.34-44.
PratibhaNaganathan1,Srirama Srinivas and HridyaIttamveettil, “Five-level torque controller-based DTC method for a cascaded three level inverter fed induction motor drive”, IET Power Electron.,© The Institution of Engineering and Technology 2017 Vol. 10 Isspp. 1223- 1230.
- Prathap Reddy, MadhukarRao, AManoranjanSahoo and SivakumarKeerthipati,“A Fault Tolerant Multilevel Inverter for Improving the Performance of Pole-Phase Modulated Nine-Phase Induction Motor Drive,” IEEE Transactions On Industrial Electronics(2003)
- Gonzalez-Prieto, M.J. Duran, J.J. Aciego, C. Martin, and F. Barrero,“Model Predictive Control of Six-phase Induction Motor Drives Using Virtual Voltage Vectors”, IEEE Transactions On Industrial Electronics.(2005) p.10
Mario Bermudez, Ignacio Gonzalez-Prieto, Federico Barrero, Hugo Guzman, Xavier Kestelynl and Mario J. Duran, “AnExperimental Assessment of Open-Phase Fault-Tolerant Virtual Vector Based Direct Torque Control in Five-Phase Induction Motor Drives”, IEEE Transactions On Power Electronics.(2006)p.4
Ignacio González-Prieto1, Mario. J. Duran1 and Federico J. Barrero, “Fault-tolerant Control of Six-phase Induction Motor Drives with Variable Current Injection”, IEEE Transactions OnPower Electronics(2014).p.123-126. Edition one.
Seyed Mohammad Jalal Rastegar Fatemi1, Navid Reza Abjadi, JafarSoltani,andSaeedAbazari,” Speed sensorless control of a six- phase induction motor drive using backstepping control”, IET Power Electron.,2014,
E.Levi Liverpool John Moores University School of Electrical Engineering Liverpool L3 3AF, UK, A.Boglietti, M.LazzariPolitecnicoh Torino Dipt. diIngegneriaElettricaIndustriale 1012. Torino, Italy(2001)
Yifan Tang, Member, IEEE, and LongyaXu, Senior Member, IEEE, “A Flexible Active and Reactive Power Control Strategy for a Variable Speed Constant Frequency Generating System,” IEEE Transactions On Power Electronics, Vol. Lo, No. 4, July 1995.
- Rahman, B.E., M.Sc, Ph.D., and W. Shepherd, D.Sc.(Eng.), “Thyristor and diode controlled variable voltage drives for 3-phase induction motors”,IEE, Vol 124,No. 9, September 1977.
BidyutMahato,RaviRaushan,Kartick Chandra Jana, “Modulation and Control of Multilevel Inverter for an Open-end Winding Induction Motor with Constant Voltage Levels and Harmonics,” IET Power Electronics.(2005)
Agrebi-Zorgani, Y., Koubaa, Y. and Boussak, M. (2010).Simultaneous Estimation of Speed and Rotor Resistance in Sensorless ISFOC Induction Motor Drive Based on MRAS Scheme. IEEE International Conference on Electrical Machines ICEM, Rome,6-8 September 2010, IEEE, pp. 1–6.
Anwin John and Jayanand B (2014) “Speed and Current Observer for Induction Motor using Extended Kalman Filter” International Journal of Engineering Research & Technology (IJERT) ISSN: 2278-0181Vol. 3 Issue 7, July – 2014.
Bilal A., Umit O., Aydin E., Mehrded E., (2004) “A Comparative Study on Non- Linear State Estimators Applied to Sensorless AC Drives: MRAS and Kalman Filter,” 30 Annual Conf. of the IEEE Ind. Electron. Society. Busan, Korea.
Benchaib, A., A. Rachid, E. Audrezet, and M. Tadjine,(1999) “Real time sliding mode observer and control of an
induction motor,” IEEE Trans. on Ind. Electronics, vol. 46, no. 1, Feb1999, pp. 128-138.
- Schauder, (1992)”Adaptive speed identification for vector control of induction motors without rotational transducers,” IEEE Transactions on Industry Applications, vol. 28, no. 5, pp. 1054-1061, September/October.
Cheng Z. C., Hai P. L., (2002) “An Application of Fuzzy-Inference-Based Neural Network in DTC System of
Induction Motor,” In Proc. First Int. Conf. on Machine Learning and Cybernetics, Beijing, p. 354-359.
Chul-Woo Park and Woo-Hyen Kwon, (2004)”Simple and robust speed sensorless vector control of induction motor using stator current based MRAC,” Electric Power Systems Research, Elsevier, Vol. 71, pp. 257–266.
Cirrincione M., Pucci M., (2005)“Sensorless direct torque control of an induction motor by a TLS-based MRAS
observer with adaptive integration,” Automatica, 41, p. 1843-1854.
Clarke, E. (1943) “Circuit Analysis of Power Systems” Vol. I, Symmetrical and Related Components”, John Wiley & Sons, New York
- Novotny and T. A. Lipo, (1996) “Vector Control and Dynamics of AC Drives” Oxford University Press Inc., New York, 1996.
- Prasad, Suresh, K. Raghuveer; (2012) “Field Oriented Control of PMSM Using SVPWM Technique” Global
Journal of Advanced Engineering Technologies, Vol1, Issue2- ISSN: 2277-6370.
- Peng and T. Fukao, (1994) “Robust speed identification for speed-sensorless vector control of induction motors,” IEEE Transactions on Industry Applications, vol. 30, no. 5, pp. 1234-1240, September/October
- Blaschke, (1972)”The principle of field-orientation as applied to the Trans vector closed-loop control systemfor rotating-field machines”, in Siemens Review 34,pp.217-22.
Farzan Rashidi (2004), “Sensorless speed control of induction motor drives using robust and adaptive neuro-fuzzy based intelligent controller ”IEEE international conference on industrial technology (ICIT), 2004, pp. 617- 627.
- Asher, A. Ferrah, K.J. Bradley; (1992) “Sensorless speed detection of inverter fed induction motors using rotor slot harmonics and fast Fourier transforms” IEEE PES meeting, pages 279{286.
- Toliyat, E. Levi and M. Raina (2003) “A Review of RFO Induction Motor Parameter Estimation Techniques”, IEEE Trans. on Energy Conversion, Vol. 18, No.2, June 2003.
J.H. Song I. Choy K.B. Kim J. Song, K.B. Lee, (2000) “Sensorless vector control of induction motor using a novel reduced-order extended luenberger observer” Conference Record of the 2000 IEEE Industry Applications Conference, 3:1828{1834.
- Yoo G. Park S. Kim, T. Park, (2001) “Speed-sensorless vector control of an induction motor using neural network speed estimation. IEEE Trans. Ind. Electronics,48(3):609{614,
Joachim Holtz, (2002) “Sensorless Control of Induction Machines—With or Without Signal Injection,”IEEE Trans. on Ind. Electrical., Vol. 53, No. 1,February, pp. 7-30.
Joachim Holtz, (2002) “Sensorless Control of Induction Motor Drives,” IEEE Proc., Vol. 90, No. 8, pp. 1359-1394, August.
- Shi, T. F. Chan, Y. K. Wong, S.L. HO; (2002) “Speed Estimation of an Induction Motor Drive Using an Optimized Extended Kalman Filter” IEEE transactions on industrial electronics, vol. 49, no. 1.
Kim Y. R., S. K. Sul and M.H. Park, (1994) “Speed sensorless vector control of induction motorusing extended Kalman filter,” IEEE Transaction on Ind. Appl., Vol. 30, no. 5, pp. 1225-1233.
Kyo B. L., Frede B., (2006) “Reduced-Order Extended Luenberger Observer Based Sensorless Vector Control Driven by Matrix Converter With Nonlinearity Compensation,” IEEE Trans. Ind. Electron., 53(1), p. 66-75.
- Harnefors, M. Hinkkanen, (2008) “Complete stability of reduced-order and full-order observers for sensorless IM
drives”, IEEE Transactions on Industrial Electronics, Vol. 55, No. 3, pp. 1319–1329.
Lipo, T. & Novotny, D. (1985). Introduction to field orientation and high performance drives. Tutorial course, IEEE LAS, 2.1-2.64.
Longya Xu, Ernesto Inoa, Yu Liu, and Bo Guan; (2012) “A New High-Frequency Injection Method for Sensorless Control of Doubly Fed Induction Machines” IEEE transactions on industry applications, vol. 48, no. 5, September/October 2012
- Hinkkanen, (2004) “Stabilization of regenerating-mode operation in sensorless induction motor drives by full- order flux observer design”, IEEE Transactions on Industrial Electronics, Vol. 51, No. 6, pp. 1318–1328, 2004
M.M.M. Negm, (2000)” Torque optimized speed control of a three phase induction motor”, in Proc.Int. Conf. power system technology, power con 2000,pp. 67-72.
- N. Marwali and A. Keyhani, (1997) “A comparative study of rotor flux based MRAS and back EMF based MRAS speed estimators for speed sensorless vector control of induction machines, “Proc. of the IEEE-IAS Annual Meeting ,pp. 160–166.
Morteza Majdi and Farzan Rashidi, (2005) “Sensorless Speed and Position Control of Induction Motor Servo Drives Using MLP Neural Network and Sliding Mode Controller” 4th WSEAS int. conf. on non-linear analysis, non-linear systems and chaos, sofia, bulgaria, october 27-29, (pp94-102)
Mugdha Bhandari, Shivaji Gavade, Shwetha S H, (2015) “Model Reference Adaptive Technique for Sensorless Speed Control of Induction Motor Using MATLAB\SIMULINK” International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: 0976-1353 Volume 14 Issue 2.
Ouhrouche M. A., (2002)“Estimation of speed, rotor flux and rotor resistance in cage induction motor using the
EKF-algorithm,” Int. J. Power and Energy Sys, p. 1-20.
Park, R.H. (1929). “Two-Reaction Theory of Synchronous Machines Generalized Method of Analysis – Part I”, AIEE Transactions, Vol. 48, pp. 716-727
Pavel, Brandstetter, Marek Dobrovsky, (2013) “Speed Estimation Of Induction Motor Using Model Reference adaptive system with kalman filter” theoretical and applied electrical engineering volume: 12, number: 1.
Peter Vas, (1993) “Parameter estimation condition monitoring a diagnosis of electrical machines” Oxford University
Press.
Peter Vas, (1998) “Sensorless vector and direct torque control” Oxford University Press.
- Zwicky, Haemmerli, R. Tanner; (1987) “A rotor speed detector for induction machines utilizing rotor slot
harmonics and active three-phase injection” EPE, Grenoble, pages 599{603, 1987.
Rashidi, F., Rashidi, M. (2012) “Design of robust sliding mode speed control with fuzzy approach for induction motor”, IEEE international conference on industrial technology (ICIT03),pp. 27-30.
- Alireza Davari, D. A. Khaburi, F. Wang, and R. M. Kennel, (2012) “Using full order and reduced order observers for robust sensorless predictive torque control of induction motors,” IEEE Trans. Power Electron., vol. 27, pp. 3424-3433.
- Ambrosii C. Ilas R. Magureanu M. Cuibus, V. Bostan, (2000) “Luenberger, kalman andneural network observers for sensorless induction motor control” Power Electronics and Motion Control Conference, 3:1256{1261
Review Of Related Studies. (n.d.). UniTopics. https://www.unitopics.com/project/material/review-of-related-studies/
“Review Of Related Studies.” UniTopics, https://www.unitopics.com/project/material/review-of-related-studies/. Accessed 22 November 2024.
“Review Of Related Studies.” UniTopics, Accessed November 22, 2024. https://www.unitopics.com/project/material/review-of-related-studies/
Here’s a typical structure for Review Of Related Studies research projects:
- The title page of Review Of Related Studies should include the project title, your name, institution, and date.
- The abstract of Review Of Related Studies should be a summary of around 150-250 words and should highlight the main objectives, methods, results, and conclusions.
- The introduction of Review Of Related Studies should provide the background information, outline the research problem, and state the objectives and significance of the study.
- Review existing research related to Review Of Related Studies, identifying gaps the study aims to fill.
- The methodology section of Review Of Related Studies should describe the research design, data collection methods, and analytical techniques used.
- Present the findings of the Review Of Related Studies research study using tables, charts, and graphs to illustrate key points.
- Interpret Review Of Related Studies results, discussing their implications, limitations, and potential areas for future research.
- Summarize the main findings of the Review Of Related Studies study and restate its significance.
- List all the sources you cited in Review Of Related Studies project, following a specific citation style (e.g., APA, MLA, Chicago).