Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard

1.0                                                        INTRODUCTION

1.1                                                Background of the study

Dams are the major sources of water supply to cities; they also play a vital role in flood control and can assist river navigation. Most of the dams are built to serve more than one purpose and their benefits are manifold. It is necessary to implement some sort of communication between the metering systems and computer models to provide support in managing the complex systems. The growing interest in the Internet of Things has become the right choice for the pre-alert system for monitoring the rise in the water level in dams. The risk rate of sudden flood occurrence opened up a way for the way the need for the real-time dam water level monitoring and a prior alerting system that ensures the public safety. The industry has always focused to devise engineering methodologies for establishment and modification of relatively easier controlling and automation methods for any scrupulous process. This paper presents the design and implementation of a control system by means of microcomputers and data transmission networks. To verify the principle operation of the Controlling design to be presented a miniature model is experimentally tested using a GSM. GSMbased water level monitoring system for dam in this paper they have introduced the idea of water level monitoring and management.

1.2                                              Statement of the problem

Water level in a dam needs to be maintained effectively to avoid complications. The quantity of water released is hardly ever correct resulting in wastage of water & it is impossible for a man to precisely control the gates without knowledge of exact water level and water inflow rate. We have designed a system in which real time things are interconnected to web. Water level sensors are placed in dam to serve the same purpose automatically and forward the status to GSM. GSM module checks that input and upload the status of water level on the monitoring unit line. By this project each and every variation of water level is informed to control room through the GSM and nearby people can be informed in time thus saving lots of lives and avoiding the unpleasant scenarios and also this system consists of Dam health monitoring system.

1.3                                         Aim and objectives of the study

This work is aimed at building a water level indicator in dams to prevent hazard.

The objectives of the work are:

  1. To build the system prototype at low cost
  2. To ensures the public safety
  • To provide real-time dam water level monitoring and a prior alerting system

1.4      Significance of the study

This study will bring solution to an overflowing of water from dam thereby preventing flooding. With this study, Dam monitoring personnel can identify or monitor the level of water in the dam without visiting the dam. This study will also serve as a means of enlightening students on how to build simple electronics circuits.

1.5      Scope of the study

The scope of this work covers building a water level indicator used for monitoring the level of water in a dam in a real time. In this study,water level sensors are placed in dam to serve the same purpose automatically and forward the status to GSM. The developed system utilizes GSM and SMS to transmit data from sensors to the respective users through their mobile phone.An Arduino UNOboardhasbeenusedasthecontrollingdevice.Thisboardisalowcostmicrocontroller,needssimpleprogrammingand canbeintegrated with other devicesvia theinput-outputinterfaces.By this project each and every variation of water level is informed to control room through the GSM and nearby people can be informed in time thus saving lots of lives and avoiding the unpleasant scenarios.

APA

Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard. (n.d.). UniTopics. https://www.unitopics.com/project/material/design-and-implementation-of-a-water-level-indicator-in-dams-to-prevent-hazard/

MLA

“Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard.” UniTopics, https://www.unitopics.com/project/material/design-and-implementation-of-a-water-level-indicator-in-dams-to-prevent-hazard/. Accessed 20 September 2024.

Chicago

“Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard.” UniTopics, Accessed September 20, 2024. https://www.unitopics.com/project/material/design-and-implementation-of-a-water-level-indicator-in-dams-to-prevent-hazard/

WORK DETAILS

Here’s a typical structure for Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard research projects:

  • The title page of Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard should include the project title, your name, institution, and date.
  • The abstract of Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard should be a summary of around 150-250 words and should highlight the main objectives, methods, results, and conclusions.
  • The introduction of Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard should provide the background information, outline the research problem, and state the objectives and significance of the study.
  • Review existing research related to Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard, identifying gaps the study aims to fill.
  • The methodology section of Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard should describe the research design, data collection methods, and analytical techniques used.
  • Present the findings of the Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard research study using tables, charts, and graphs to illustrate key points.
  • Interpret Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard results, discussing their implications, limitations, and potential areas for future research.
  • Summarize the main findings of the Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard study and restate its significance.
  • List all the sources you cited in Design And Implementation Of A Water Level Indicator In Dams To Prevent Hazard project, following a specific citation style (e.g., APA, MLA, Chicago).