ABSTRACT
Power supply and failure is a frequent experience that occurs in our mains. Power restoration is a period of time when the electricity supply to a particular building or area is restored, because of replacement or servicing damage to the cables or any other reason.
For us to be notified when the power restoration condition has occurred in our laboratory a power monitoring device is used. This system indicates when there is power resumption in our laboratory through alarm indication. As soon as the system experiences power resumption user will receive a signal from an alarm. The aim of this work is to carry out the building such a device.
TABLE OF CONTENT
TITLE PAGE
APPROVAL PAGE
DEDICATION
ACKNOWLEDGEMENT
ABSTRACT
CHAPTER ONE
INTRODUCTION
1.1 BACKGROUND OF THE PROJECT
1.2 PROBLEM STATEMENT
1.3 OBJECTIVE OF THE PROJECT
1.4 PURPOSE OF THE PROJECT
1.5 SIGNIFICANCE OF THE PROJECT
1.6 APPLICATION OF THE PROJECT
1.7 SCOPE OF THE PROJECT
1.8 METHODOLOGY
1.9 PROJECT WORK ORGANIZATION
CHAPTER TWO
LITERATURE REVIEW
2.1 REVIEW OF ELECTRICAL POWER SUPPLY
2.2 HISTORY ELECTRIC POWER SYSTEM
2.3 HISTORY OF POWER FAILURE AND SYSTEM RELIABILITY
2.4 TYPES OF POWER FAILURE SIGNAL
2.5 TYPES OF POWER FAILURE
2.6 PROTECTING THE POWER SYSTEM FROM FAILURE
2.7 RESTORING POWER AFTER A WIDE-AREA OUTAGE
2.8 REVIEW OF RELATED STUDIES
CHAPTER THREE
CONSTRUCTION
3.1 DESCRIPTION OF THE SYSTEM BUILDING BLOCKS
3.3 CIRCUIT DIAGRAM
3.4 OPERATION PRINCIPLE OF THE SYSTEM
3.4 CIRCUIT DESCRIPTION
3.5 COMPONENT LIST
3.6 COMPLETE CIRCUIT DIAGRAM OF THE SYSTEM
3.7 DESCRIPTION OF MAJOR COMPONENTS USED
CHAPTER FOUR
4.0 TEST AND RESULT ANALYSIS
4.1 CONSTRUCTION PROCEDURE AND TESTING ANALYSIS
4.2 CASING AND PACKAGING
4.3 ASSEMBLING OF SECTIONS
4.4 TESTING OF SYSTEM OPERATION
4.5 INSTALLATION OF THE COMPLETED DESIGN
4.6 PROBLEM ENCOUNTERED
CHAPTER FIVE
5.1 CONCLUSION
5.2 RECOMMENDATION
5.3 REFERENCES
CHAPTER ONE
1.0 INTRODUCTION
1.1 BACKGROUND OF THE STUDY
In modern society, it is impossible to imagine life without electricity. Modern equipment requires a continuous supply of electricity. Not only industry, but also in the household. Take the case of an ordinary refrigerator. If you experience a power off situation, your food will be spoil. But much more important, what if the power failure “spoils” your business. For example, uninterrupted power supply is needed for your server, which manages your accounting programme or provides uninterrupted operation of your website (Dobson et al., 2017).
Of course, in most critical applications, uninterruptible power supplies (UPS) are used, but this is not always the case. Also, these devices cannot provide continuous operation in the event of remote power off. Often you need to take other action according to the situation.
For us to be notified when the power ON condition has occurred a power monitoring device is used. This system indicates when there is resumption in our mains through alarm indication. As soon as the system experiences power resumption you will receive a signal from an alarm (Dobson et al., 2017). This study discusses mains electricity alert system for laboratory.
1.2 PROBLEM STATEMENT
Power failure in laboratory can be irritating, frustrating and devastating, affect lab equipment and at the same time affect the happiness of the laboratory users. It is quite unfortunate that sometimes when power is restored the laboratory users will not be aware most especially when there is noise and no electricity indicator. In other to overcome this problem, this device was designed. This device is designed to inform you when the power is restored in the laboratory.
1.3 AIM AND OBJECTIVE OF THE PROJECT
The main aim of the project is to design a power monitoring device that will trigger a buzzer when the mains supply is restored in the laboratory. The objectives of this work are:
- To indicate that the mains have been restored in the laboratory
- To protect lab equipment from damages.
- To build an electricity supply alerting device
1.4 PURPOSE OF THE PROJECT
The purpose of this work is to build a power monitoring device that monitors power resumption in the laboratory thereby informing the user to switch off their alternative power supply.
1.5 SIGNIFICANCE OF THE PROJECT
Laboratory electricity alert system notifies one by alarm when laboratory equipment power supply is restored. If you have important equipment you want to run with mains and want to know if there has been a power supply so that you power the device, this app can help you by telling you when electric power is supplied (Dobson et al., 2017).
Working on this topic has serve as a means of learning how to configure astable and monostable multivibrator.
1.6 APPLICATION OF THE PROJECT
Typical uses of electricity alert system include monitoring (Peter, 2014):
* fridges/freezers;
* fish tanks/aquariums;
* sump pumps;
* computer equipment;
* heating systems;
* chemical storage;
* and many other applications.
1.7 SCOPE OF THE PROJECT
The scope of this work focused on building a device that will alert the user a buzzer when the mains supply is restored in the laboratory. At the same time, the light emitting diode will be turned ON. Once the buzzer sound, one will know that there is restoration in the laboratory (Peter, 2014).
1.8 METHODOLOGY
To achieve the aim and objectives of this work, the following are the steps involved:
- Study of the previous work on the project so as to improve it efficiency.
- Draw a block diagram.
- Test for continuity of components and devices,
- Design of the alarm was carried out.
- Studying of various component used in circuit.
- Construct the circuit.
- Finally, the whole device was cased and final test was carried out.
1.9 PROJECT WORK ORGANISATION
The work is organized as follows: chapter one discuses the introductory part of the work, chapter two presents the literature review of the study, chapter three describes the methods applied, chapter four discusses the results of the work, chapter five summarizes the research outcomes and the recommendations.
Design And Construction Of Laboratory Electricity Alert System. (n.d.). UniTopics. https://www.unitopics.com/project/material/design-and-construction-of-laboratory-electricity-alert-system/
“Design And Construction Of Laboratory Electricity Alert System.” UniTopics, https://www.unitopics.com/project/material/design-and-construction-of-laboratory-electricity-alert-system/. Accessed 22 November 2024.
“Design And Construction Of Laboratory Electricity Alert System.” UniTopics, Accessed November 22, 2024. https://www.unitopics.com/project/material/design-and-construction-of-laboratory-electricity-alert-system/
Here’s a typical structure for Design And Construction Of Laboratory Electricity Alert System research projects:
- The title page of Design And Construction Of Laboratory Electricity Alert System should include the project title, your name, institution, and date.
- The abstract of Design And Construction Of Laboratory Electricity Alert System should be a summary of around 150-250 words and should highlight the main objectives, methods, results, and conclusions.
- The introduction of Design And Construction Of Laboratory Electricity Alert System should provide the background information, outline the research problem, and state the objectives and significance of the study.
- Review existing research related to Design And Construction Of Laboratory Electricity Alert System, identifying gaps the study aims to fill.
- The methodology section of Design And Construction Of Laboratory Electricity Alert System should describe the research design, data collection methods, and analytical techniques used.
- Present the findings of the Design And Construction Of Laboratory Electricity Alert System research study using tables, charts, and graphs to illustrate key points.
- Interpret Design And Construction Of Laboratory Electricity Alert System results, discussing their implications, limitations, and potential areas for future research.
- Summarize the main findings of the Design And Construction Of Laboratory Electricity Alert System study and restate its significance.
- List all the sources you cited in Design And Construction Of Laboratory Electricity Alert System project, following a specific citation style (e.g., APA, MLA, Chicago).