Design And Construction Of An Automatic Intruder Alarm System

ABSTRACT

This device warns the trespasser infrared system or Infrared Intruder Alarm circuit that interesting. By when there is a person passes or cut the light infrared. The system will clearly warn immediately, command give an indication through 7-segment display

Circuit diagram of this device uses an infrared sensor to sense intrusions. Infra red rays reflected from a static object will be in one phase, and the rays reflected from a moving object will be in another phase. The circuit uses this principle to sense the motion. The IC1 (NE 555) is wired as an astable multivibrator. The IR diode connected at the output of this IC produces infrared beams of frequency 5Khz. These beams are picked by the infrared sensor, photo transistor Q1. At normal condition, that is, when there is no intrusion the output pin (7) of IC2 will be low. When there is an intrusion the phase of the reflected waveforms has a difference in phase and this phase difference will be picked by the IC2. Now the pin 7 of the IC 2 goes high to indicate the intrusion.

 CHAPTER ONE

1.0                                                        INTRODUCTION

Intruder alarm is designed to detect intrusion – unauthorized entry – into a building or area. Security alarms are used in residential, commercial, industrial, and military properties for protection against burglary (theft) or property damage, as well as personal protection against intruders. Car alarms likewise protect vehicles and their contents. Prisons also use security systems for control of inmates.

Some alarm systems serve a single purpose of burglary protection; combination systems provide both fire and intrusion protection. Intrusion alarm systems may also be combined with closed-circuit television surveillance systems to automatically record the activities of intruders, and may interface to access control systems for electrically locked doors. Systems range from small, self-contained noisemakers, to complicated, multi-area systems with computer monitoring and control.

1.1                                         BACKGROUND OF THE PROJECT

The need for having home protection has always been there. But in the recent times, considering a dramatic rise in petty crimes like robbery and theft, the need has been more strongly felt to have a fool proof protection of the belongings and the family members. Home security has come a long way in the last few decades. It was in the hands of a guard who manually provided surveillance during nights in the earlier days, but it was not fool proof as it was only normal for him to have momentary lapse of concentration.

The guard was also susceptible to sleep at times. It was then that home alarm system based upon electronic circuits were developed which proved to be highly reliable and were appreciated by the people as they were relieved from constant monitoring of their homes.

1.2                                             OBJECTIVE OF THE PROJECT

Intruder alarms are automatic home monitoring devices to monitor and alert in case of a burglary attempt at that place – house or a commercial place. Our objective is to ensure security of property using our device.

1.3                                              PURPOSE OF THE PROJECT

This project proposes the development of security system for form houses and residential houses.

1.4                                         SIGNIFICANCE OF THE PROJECT

This circuit warns the trespasser infrared system or Infrared Intruder Alarm circuit that interesting. By when there is a person passes or cut the light infrared. The system will clearly warn immediately, command give relay work, and build current give indication through seven segment display.

1.5                                                 SCOPE OF THE PROJECT

In an extremely mechanized word such as today’s it is necessary to make our life better, convertible and economical. This is the purpose for which the Electronic house is developed.

The project composed of the:

  1. Transmitter
  2. Receiver
  3. Seven segment counter

TRANSMITTER :The transmitter section is built around IC 555 (IC1),Ø which is wired as an astable multivibrator. It produces about 38kHz frequency.Ø IR LED1 emits 38kHz modulated signals up to aØ distance of 4.6 metres (15 feet). The modulated IR beam from the transmitterØ continuously falls on the receiver section.

RECEIVER:  The receiver sensor TSOP1738 responds to 38kHz frequency. The modulated IR beam falling on receiver sensor TSOP1738 makes its output low. When somebody crosses the path of IR rays it senses this and its output goes high momentarily, which triggers the flip-flop. The IR transmitter and receiver units are mounted opposite to each other on the sides of entry door or gate.

1.6                                          APPLICATION OF THE PROJECT

This device is used in the following places as:

  • Home Security Systems.
  • Prisons Security.
  • Vehicle Security.
  • Broadband alarm monitoring.
  • Glass Break.
  • Property Theft Alarm

1.7                       PROJECT WORK ORGANISATION

The various stages involved in the development of this project have been properly put into five chapters to enhance comprehensive and concise reading. In this project thesis, the project is organized sequentially as follows:

Chapter one of this work is on the introduction to this study. In this chapter, the background, significance, objective limitation and problem of this study were discussed.

Chapter two is on literature review of the study. In this chapter, all the literature pertaining to this work was reviewed.

Chapter three is on design methodology. In this chapter all the method involved during the design and construction were discussed.

Chapter four is on testing analysis. All testing that result accurate functionality was analyzed.

Chapter five is on conclusion, recommendation and references.

APA

Design And Construction Of An Automatic Intruder Alarm System. (n.d.). UniTopics. https://www.unitopics.com/project/material/design-and-construction-of-an-automatic-intruder-alarm-system/

MLA

“Design And Construction Of An Automatic Intruder Alarm System.” UniTopics, https://www.unitopics.com/project/material/design-and-construction-of-an-automatic-intruder-alarm-system/. Accessed 22 November 2024.

Chicago

“Design And Construction Of An Automatic Intruder Alarm System.” UniTopics, Accessed November 22, 2024. https://www.unitopics.com/project/material/design-and-construction-of-an-automatic-intruder-alarm-system/

WORK DETAILS

Here’s a typical structure for Design And Construction Of An Automatic Intruder Alarm System research projects:

  • The title page of Design And Construction Of An Automatic Intruder Alarm System should include the project title, your name, institution, and date.
  • The abstract of Design And Construction Of An Automatic Intruder Alarm System should be a summary of around 150-250 words and should highlight the main objectives, methods, results, and conclusions.
  • The introduction of Design And Construction Of An Automatic Intruder Alarm System should provide the background information, outline the research problem, and state the objectives and significance of the study.
  • Review existing research related to Design And Construction Of An Automatic Intruder Alarm System, identifying gaps the study aims to fill.
  • The methodology section of Design And Construction Of An Automatic Intruder Alarm System should describe the research design, data collection methods, and analytical techniques used.
  • Present the findings of the Design And Construction Of An Automatic Intruder Alarm System research study using tables, charts, and graphs to illustrate key points.
  • Interpret Design And Construction Of An Automatic Intruder Alarm System results, discussing their implications, limitations, and potential areas for future research.
  • Summarize the main findings of the Design And Construction Of An Automatic Intruder Alarm System study and restate its significance.
  • List all the sources you cited in Design And Construction Of An Automatic Intruder Alarm System project, following a specific citation style (e.g., APA, MLA, Chicago).