Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51)

ABSTRACT

This project work is on a breathalyzer circuit using 8051 microcontroller. This device outputs the blood alcohol content (BAC) from the breath. The BAC is displayed in percentage on a 3 digit seven segment display. The microcontroller used if AT89S51 which belongs to the 8051 family and the alcohol sensor is MQ135 gas sensor from Futurelec.

TABLE OF CONTENTS

 TITLE PAGE

APPROVAL PAGE

DEDICATION

ACKNOWLEDGEMENT

ABSTRACT

TABLE OF CONTENT

CHAPTER ONE

  • INTRODUCTION
  • OBJECTIVE OF THE PROJECT
  • SIGNIFICANCE OF THE PROJECT
  • PURPOSE OF THE PROJECT
  • LIMITATION OF THE PROJECT
  • APPLICATION OF THE PROJECT
  • FUTURE DEVELOPMENT OF THE PROJECT
  • PROJECT ORGANIZATION

CHAPTER TWO

LITERATURE REVIEW

2.0      LITERATURE REVIEW
2.1      REVIEW OF ALCOHOL SENSING

2.2      REVIEW OF ALCOHOL USAGE

2.3        FACTS ABOUT ALCOHOL IN THE FACTORY/WORKPLACE

2.4     BLOOD ALCOHOL CONTENT

2.5    REVIEW OF DIFFERENT ALCOHOL TESTING METHODS

 CHAPTER THREE

3.0      CONSTRUCTION METHODOLOGY
3.1      BLOCK DIAGRAM OF THE SYSTEM

3.2      CIRCUIT DIAGRAM

3.3      CIRCUIT DESCRIPTION

3.4      SYSTEM OPERATION

3.5      COMPONENTS LIST

3.6     POWER SUPPLY UNIT

CHAPTER FOUR

4.0       RESULT ANALYSIS

4.1      CONSTRUCTION PROCEDURE AND TESTING

4.2      ASSEMBLING OF SECTIONS

4.3      CONSRUCTION OF THE CASING

4.4     TESTING

CHAPTER FIVE

  • CONCLUSIONS
  • RECOMMENDATION

5.3     REFERENCES

MQ135 gas sensor.

MQ135 is a stable and sensitive gas sensor which can detect  ammonia, carbon dioxide, alcohol, smoke, nitrogen dioxide etc. The sensor consists of a tin dioxide sensitive layer inside aluminium oxide micro tubes, measuring electrode and a heating element inside a tubular aluminium casing. The front end of the sensor is covered using a stainless steel net and  the rear side holds the connection terminals.

The ethyl alcohol present in the breath is oxidized into acetic acid while passing over the heating element. This ethyl alcohol falls on the  tin dioxide sensing layer and as a result its resistance decreases. This resistance variation  is converted into a suitable voltage variation using an external load resistor. The typical connection arrangement of an MQ135 alcohol sensor is shown below.

MQ135 alcohol sensor

MQ135 has different resistance values at different temperature and different concentration of gases. The manufacturer recommends to calibrate the sensor at 100ppm of ammonia or 50ppm of alcohol. The recommended value of the load resistor is between 10K to 47K.

Circuit diagram.

The voltage output of the alcohol sensor is converted into a digital format using the ADC0804 (IC1). The Vref/2 pin of the ADC is held at 1.28V using the voltage divider network made of R14 and R15. Vref/2 =1.28V means the step size of the ADC will be 10mV and the output of the ADC will increment by one bit for every 10mV increment in the analog input. Refer the datasheet of ADC0804 for a better grasp. Digital out of the ADC (D0 to D7)  is interfaced to Port1 of the microcontroller. Control signals CS, RD, WR, INTR are obtained from the microcontrollers P3.7, P3.6, P3.5, P3.4 pins respectively. R9 and C1 are associated with the clock circuitry of the ADC0804.

Capacitor C3 connected between Vin+ and Vin- of the ADC0804 filters of noise (if any) in the sensor output. If C3 is not used the digital output of the ADC will not be stable. This filter capacitor will surely induce some lag in the ADC response but it is not very relevant in this entry level application. The microcontroller performs required manipulations on the ADC digital output in order to convert it into BAC % and displays it on the three digit seven segment display. Port0 of the microcontroller is interfaced to the multiplexed three digit seven segment display. The drive signals for the threes digits are obtained from the microcontroller’s P3.0, P3.1, P3.2 pins respectively.

Program.

ORG 00H

MOV P1,#11111111B

MOV P0,#00000000B

MOV P3,#00000000B

MOV DPTR,#LUT

MAIN: MOV R4,#250D

CLR P3.7

SETB P3.6

CLR P3.5

SETB P3.5

WAIT: JB P3.4,WAIT

CLR P3.7

CLR P3.6

MOV A,P1

MOV R5,A

SUBB A,#86

JC NEXT

SETB P3.3

CLR PSW.7

NEXT: MOV A,R5

SUBB A,#115D

JNC LABEL

MOV A,#00000000B

CLR PSW.7

LABEL: MOV B,#5D

MUL AB

MOV B,#8D

DIV AB

MOV B,#10D

DIV AB

MOV R6,A

MOV R7,B

DLOOP:SETB P3.0

MOV P0,#01000000B

ACALL DELAY

CLR P3.0

SETB P3.1

MOV A,R6

ACALL DISPLAY

MOV P0,A

ACALL DELAY

CLR P3.1

SETB P3.2

MOV A,R7

ACALL DISPLAY

MOV P0,A

ACALL DELAY

CLR P3.2

DJNZ R4,DLOOP

SJMP MAIN

DELAY: MOV R3,#255D

LABEL1: DJNZ R3,LABEL1

RET

DISPLAY: MOVC A,@A+DPTR

CPL A

RET

LUT: DB 3FH

DB 06H

DB 5BH

DB 4FH

DB 66H

DB 6DH

DB 7DH

DB 07H

DB 7FH

DB 6FH

END

Notes.

  • The MQ135 gas sensor requires around 5 minutes of preheat before the first use.
  • The MQ135 takes few minutes to retrace back to its normal condition after a positive test (alcohol present in the breath).
  • If there is no alcohol in the breath  the sensor output will swing back to its normal condition very fast.
  • Read these articles Interfacing seven segment display to 8051 microcontroller , Interfacing ADC to 8051 microcontroller  before attempting this project.
  • This breathalyzer circuit is just an entry level one and is not suitable for high end applications such as law enforcement or laboratory application.
  • The logic for converting the digital output of ADC into BAC percentage was obtained using approximation techniques.
APA

Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51). (n.d.). UniTopics. https://www.unitopics.com/project/material/design-and-construction-of-an-alcohol-breathalyzer-circuit-using-8051-microcontroller-at89s51/

MLA

“Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51).” UniTopics, https://www.unitopics.com/project/material/design-and-construction-of-an-alcohol-breathalyzer-circuit-using-8051-microcontroller-at89s51/. Accessed 22 November 2024.

Chicago

“Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51).” UniTopics, Accessed November 22, 2024. https://www.unitopics.com/project/material/design-and-construction-of-an-alcohol-breathalyzer-circuit-using-8051-microcontroller-at89s51/

WORK DETAILS

Here’s a typical structure for Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51) research projects:

  • The title page of Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51) should include the project title, your name, institution, and date.
  • The abstract of Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51) should be a summary of around 150-250 words and should highlight the main objectives, methods, results, and conclusions.
  • The introduction of Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51) should provide the background information, outline the research problem, and state the objectives and significance of the study.
  • Review existing research related to Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51), identifying gaps the study aims to fill.
  • The methodology section of Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51) should describe the research design, data collection methods, and analytical techniques used.
  • Present the findings of the Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51) research study using tables, charts, and graphs to illustrate key points.
  • Interpret Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51) results, discussing their implications, limitations, and potential areas for future research.
  • Summarize the main findings of the Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51) study and restate its significance.
  • List all the sources you cited in Design And Construction Of An Alcohol Breathalyzer Circuit Using 8051 Microcontroller (At89S51) project, following a specific citation style (e.g., APA, MLA, Chicago).