Design And Construction Of A Mains Supply Failure Backup Light

ABSTRACT

In the event of a sudden blackout at night, this mains supply failure backup light switches on automatically to provide sufficient light for around 30 seconds (extendible), which is enough to switch on an emergency lamp or light up a candle. The device is simple, low-cost and maintenance-free as it uses no battery, bulky transformer or incandescent bulb. It operates off AC voltages ranging from 100V to 300V RMS, which is particularly useful for rural areas where fluctuations in voltage are excessive. The circuit uses a white LED as the light source and an electrolytic capacitor for backup power, which makes it a ‘fit and forget’ circuit requiring no frequent replacement of the battery or bulb.

TABLE OF CONTENTS

COVER PAGE

TITLE PAGE

APPROVAL PAGE

DEDICATION

ACKNOWELDGEMENT

ABSTRACT

CHAPTER ONE

1.0      INTRODUCTION

1.1      BACKGROUND OF THE PROJECT

  • PURPOSE OF THE PROJECT
  • AIM OF THE PROJECT
  • OBJECTIVE OF THE PROJECT
  • PURPOSE OF THE PROJECT
  • LIMITATION OF THE PROJECT
  • ADVANTAGES OF THE PROJECT
  • PROBLEM OF THE PROJECT
  • APPLICATION OF THE PROJECT
  • RESEARCH QUESTION
  • PROJECT ORGANISATION

CHAPTER TWO

LITERATURE REVIEW

  • OVERVIEW OF THE STUDY
  • REVIEW OF THE RELATED STUDY

CHAPTER THREE

3.0     CONSTRUCTION METHODOLOGY

3.1      BASIC OF THE SYSTEM

3.2      BLOCK DIAGRAM OF THE SYSTEM

3.3      SYSTEM OPERATION

3.4      CIRCUIT DIAGRAM

3.5      CIRCUIT DESCRIPTION

3.6     DESCRIPTION OF COMPONENTS USED

3.7      POWER SUPPLY UNIT

CHAPTER FOUR

4.0      TESTING AND RESULTS

  • CONSTRUCTION PROCEDURE AND TESTING
  • INSTALLATION OF THE COMPLET DESIGN
  • ASSEMBLING OF SECTIONS
  • TESTING OF SYSTEM OPERATION
  • COST ANALYSIS

CHAPTER FIVE

  • CONCLUSION
  • RECOMMENDATION
  • REFERENCES

Mains Supply Failure Backup Light

The circuit is simple, low-cost and maintenance-free as it uses no battery, bulky transformer or incandescent bulb. It operates off AC voltages ranging from 100V to 300V RMS, which is particularly useful for rural areas where fluctuations in voltage are excessive. The circuit uses a white LED as the light source and an electrolytic capacitor for backup power, which makes it a ‘fit and forget’ circuit requiring no frequent replacement of the battery or bulb.

Mains Supply Failure Backup Light

Capacitors C1 and C2, resistors R1 and R2, and diodes D1 through D4 provide DC power for charging capacitor C4 when AC mains is available. Zener diodes ZD1 and ZD2 regulate the DC supply to 24 volts and capacitor C3 removes the ripples. Transistors T1 and T2 are used to switch on the white LED (LED1) when mains fails. Capacitor C4 is used as a storage capacitor in place of a battery.

When mains is available, capacitor C4 charges to 24 volts through diode D5. Transistor T1 is biased through resistor R3 to hold the base of transistor T2 to ground, switching off the white LED. If AC power fails, transistor T1 will lose its bias and transistor T2 will get biased through resistor R4 to switch on the white LED (LED1). LED1 will glow for a duration depending on the value of capacitor C4 used and then dim gradually.

Advertisement

The time duration for which the white LED glows can be increased by replacing C4 with a higher-value capacitor or connecting another 4700µF, 35V capacitor in parallel with C4 (see the table).

Construction & testing

Care must be taken while testing and installing the circuit as it contains live voltage in the power supply section. LED reflectors/holders can be used to focus the light. It is best fitted with unused fan/tube holders at the roof. The mains supply for the circuit should remain switched on all the time.

 

APA

Design And Construction Of A Mains Supply Failure Backup Light. (n.d.). UniTopics. https://www.unitopics.com/project/material/design-and-construction-of-a-mains-supply-failure-backup-light/

MLA

“Design And Construction Of A Mains Supply Failure Backup Light.” UniTopics, https://www.unitopics.com/project/material/design-and-construction-of-a-mains-supply-failure-backup-light/. Accessed 20 September 2024.

Chicago

“Design And Construction Of A Mains Supply Failure Backup Light.” UniTopics, Accessed September 20, 2024. https://www.unitopics.com/project/material/design-and-construction-of-a-mains-supply-failure-backup-light/

WORK DETAILS

Here’s a typical structure for Design And Construction Of A Mains Supply Failure Backup Light research projects:

  • The title page of Design And Construction Of A Mains Supply Failure Backup Light should include the project title, your name, institution, and date.
  • The abstract of Design And Construction Of A Mains Supply Failure Backup Light should be a summary of around 150-250 words and should highlight the main objectives, methods, results, and conclusions.
  • The introduction of Design And Construction Of A Mains Supply Failure Backup Light should provide the background information, outline the research problem, and state the objectives and significance of the study.
  • Review existing research related to Design And Construction Of A Mains Supply Failure Backup Light, identifying gaps the study aims to fill.
  • The methodology section of Design And Construction Of A Mains Supply Failure Backup Light should describe the research design, data collection methods, and analytical techniques used.
  • Present the findings of the Design And Construction Of A Mains Supply Failure Backup Light research study using tables, charts, and graphs to illustrate key points.
  • Interpret Design And Construction Of A Mains Supply Failure Backup Light results, discussing their implications, limitations, and potential areas for future research.
  • Summarize the main findings of the Design And Construction Of A Mains Supply Failure Backup Light study and restate its significance.
  • List all the sources you cited in Design And Construction Of A Mains Supply Failure Backup Light project, following a specific citation style (e.g., APA, MLA, Chicago).
WORK DETAILS