Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel

ABSTRACT

Samples of water from the different hostels in campus II and other source of water production namely Ajali-owa water, from bore hole 9th mile and spring water from GRA water board were water collecterd and analysed using total plate count and multiple tube fermentaton techniques coliform. The results shows no coliforms in production water from Ajali-owa and in GRA spring water reservaiour and no coliform in 9th mile bore hole water, 14 organism and 149 cfu/ml plate counts were obtained from tap water in IMT campus II hostel 7 coliform and Tocful / ml plate count from well water and 28 coliform and 280 cfu/ml plate count from spillage waste water. These results obtained show that tap water consumed in IMT campus II did not meet with NAFDAC and WHO standards. Preventive measures such as proper treatment of these water should be encourage and all pipes in campus II should be checked for leakages

TABLE OF CONTENTS

Title page
Certification
Dedication
Acknowledgement
Abstract
Table of content

1.0 CHAPTER ONE
Introduction
1.1 Aims / objectives of the study
1.2 Statement of problems
1.3 Hypothesis
1.4 Scope of limitation

CHAPTER TWO
Literature review
2.1 The major group of biological Pollutions of water
2.2 Source of water supply
2.3 Source of water pollution
2.4 Treatment of water sample
2.5 International standard for drinking water
2.6 Diseases from water

CHAPTER THREE
3.0 Materials & methods
3.0 Materials
3.1 Media preparation
3.2 Collection of samples
3.3 Collection of samples
3.4 Methods of water analysis
3.5 Determination of PH
3.5.1 Determination of bacteria of the coliform
3.5.2 Culture techniques
3.5.3 Plate count technique
3.5.4 Presumption coliform (multiple tube fermebtation
3.5.4 Confirmatory test
3.5.5 Completed test
3.5.6 Test for indole
3.5.7 Methyl red test
3.5.8 Sugar test
3.5.9 Oxidase test
3.5.10 Catakase test
3.5.11 The slide cougulase test
3.5.12 Gram stain techniques
3.5.13 Detection of faecal stredtococci
3.5.14 Detection of escherichi coli test
3.5.15 Organism suspected after gram staining

CHAPTER FOUR
RESULTS

CHAPTER FIVE
Discussion

CHAPTER SIX
6.1 Conclusion
6.2 Recommendation
References
Appendix

APA

Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel. (n.d.). UniTopics. https://www.unitopics.com/project/material/comparative-analysis-of-microbial-load-of-the-enugu-main-water-production-and-water-available-to-imt-campus-ii-hostel/

MLA

“Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel.” UniTopics, https://www.unitopics.com/project/material/comparative-analysis-of-microbial-load-of-the-enugu-main-water-production-and-water-available-to-imt-campus-ii-hostel/. Accessed 21 November 2024.

Chicago

“Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel.” UniTopics, Accessed November 21, 2024. https://www.unitopics.com/project/material/comparative-analysis-of-microbial-load-of-the-enugu-main-water-production-and-water-available-to-imt-campus-ii-hostel/

WORK DETAILS

Chapters:
6
Pages:
49
Words:
5928

Here’s a typical structure for Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel research projects:

  • The title page of Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel should include the project title, your name, institution, and date.
  • The abstract of Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel should be a summary of around 150-250 words and should highlight the main objectives, methods, results, and conclusions.
  • The introduction of Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel should provide the background information, outline the research problem, and state the objectives and significance of the study.
  • Review existing research related to Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel, identifying gaps the study aims to fill.
  • The methodology section of Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel should describe the research design, data collection methods, and analytical techniques used.
  • Present the findings of the Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel research study using tables, charts, and graphs to illustrate key points.
  • Interpret Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel results, discussing their implications, limitations, and potential areas for future research.
  • Summarize the main findings of the Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel study and restate its significance.
  • List all the sources you cited in Comparative Analysis Of Microbial Load Of The Enugu Main Water Production And Water Available To Imt Campus Ii Hostel project, following a specific citation style (e.g., APA, MLA, Chicago).